Siemens Building Technologies Basic Documentation LMU54... / LMU64... CC1P7494en
HVAC Products Contents 07.11.2002
Heating circuits...........................................................................30
Room setpoint ............................................................................32
Configuration of the heating circuits...............................................34
DHW circuit................................................................................35
3.3 Acquisition of actual values ..................................................................37
Assignment of analog sensors ......................................................37
Temperatures .............................................................................37
Display of ionization current..........................................................38
3.4 Supervisory functions ..........................................................................39
Temperature limiter function.........................................................39
Flue gas temperature supervision..................................................39
Plausibility check of sensor .......................................................39
Function.................................................................................39
Electronic (S)LT..........................................................................40
Handling faults ........................................................................40
Flow switch / water pressure supervision........................................42
Function of flow switch..............................................................42
Function of pressure switch.......................................................42
Pressure sensor..........................................................................42
Static supervision.....................................................................43
Dynamic supervision ................................................................44
Load limitation............................................................................45
Speed limitation..........................................................................48
Limitation of ionization current.......................................................48
3.5 Boiler control......................................................................................49
Frost protection for the boiler........................................................49
Controller delay ..........................................................................49
Controller delay due to parameterization.....................................49
Controller delay due to SLT criterion...........................................50
Controller configuration................................................................50
Transfer of setpoint / actual value...............................................50
Determining the controller coefficients ........................................50
Heat output limits.....................................................................51
Boiler temperature control............................................................52
2-position control .....................................................................52
Minimum boiler pause time........................................................52
Boiler cycling protection...............................................................52
Dynamic switch-off differential....................................................53
Modulating control, conventional................................................54
3.6 Hydraulic system management (HSM)...................................................55
Frost protection for the plant .........................................................55
3.7 Consumer management (CM) ..............................................................56
Determining the demands for heat.................................................56
Priorization of demands for heat ................................................56
Determining the temperature demand............................................57
Temperature limitation..............................................................58
Summer / winter (S / W) changeover..............................................59
3.8 Electronically controlled PWM heating circuit pump.................................61
General......................................................................................61
Introduction................................................................................61
Notes .....................................................................................61