6. Installation of transmitter
Step 2
Take the SENSORPROM
®
memory unit from
the sensor. Mount the SENSORPROM
®
unit in
the wall mounting unit as shown. The text on the
SENSORPROM
®
unit must face towards the
wall bracket.
Mount an earth wire between PE on connection
board and bottom of connection box.
6.2.3
Remote installation -
Wall mounting
(continued)
MAG 6000
Step 3
Mount the connection plate in the terminal box.
Fix the connection plate with the two diagonal
opposite screws.
Fit the coil
B , electrode A , s u pp l y C a n d o u t pu t
cables
D respectively and tighten the cable
glands to obtain optimum sealing. Please see
the wiring diagram in “Electrical connections”
Step 4
Mount the transmitter on the terminal box.
Caution
Exposing the transmitter
to direct sunlight may
increase the operating
temperature above its
specified limit, and
decrease display visibilty
Attention
When remote mounted, power supply PE wire
must be connected to PE terminal.
Coil cable shield must be connected to SHIELD
terminal.
Use the supplied insulating tube to insulate the
core shield.