EasyManua.ls Logo

Siemens Milltronics Millpulse 600 - Specifications

Siemens Milltronics Millpulse 600
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7ML19985DG02 Milltronics MillPulse 600 – INSTRUCTION MANUAL Page 3
Specifications
Switching Capability
• voltage: 18 to 48 V AC/DC +/-10%, 50/60 Hz (Jumper In)
60 to 135 V AC/DC +/-10%, 50/60 Hz (Jumper Out)
• current 5 to 400 mA continuous
2 A surge for 20 msec at 1 operation per second
Voltage Drop
•8 V
Residual Current
•1.5 mA
Fuse
• 1A, 250 V, SLO-BLO, 4.5 x 14.5 mm (not operator replaceable)
Switch Duration
• on: 50 msec minimum
• off: 50 msec minimum
Operating Limit
• 600 pulses per minute maximum
Operating Temperature
• -45 to 60 °C (-45 to 140 °F)
Display
• red LED for switch status
Construction
• probe body: aluminum
• process mounting: 2” NPSL
• connection box: aluminum
3/4” NPT conduit entrance
4 screw terminals for maximum 12 AWG wire size
• gasketing: neoprene