Connectable components
9.3 PP 72/48D 2/2A PN
NCU 7x0.3 PN
130 Manual, 09/2011, 6FC5397-1EP40-0BA0
● Technical data:
Table 9- 45 Electrical specification of the digital inputs:
Digital inputs min. max. Nominal
High-level voltage (U
H
) 15 V 30 V 24 V
Input current I
IN
at V
H
2 mA 15 mA -
Low-level voltage (U
L
) -30 V +5 V 0 V
Signal delay time T
PHL
0.5 ms 3 ms -
Signal delay time T
PHL
rapid inputs (X222: DI 3.0 to
3.7)
- - 600 μs
Digital outputs
● Features
– No galvanic isolation.
– Protection against: Short-circuit, overtemperature, and loss of ground.
– Automatic disconnection in case of undervoltage.
● Terminal assignment for the digital outputs:
The following figure shows an example of the terminal assignment for the digital outputs
on connector X111. Connectors X222 and X333 are assigned analogously.
([WSRZHUVXSSO\
9'&VWDELOL]HG
;;;
3LQQXPEHU
'ULYHU
'ULYHU
'ULYHU
5HOD\
33'$31
9
9
'2&20[
:
:
:
:
1 (M)
0
Figure 9-18 Terminal assignment for the digital outputs
CAUTION
A max. current of I
out
= 0.25 A at X111, X222, X333 where the demand factor is 100%:
Pin 2 must not be exceeded.