7.8 PROFIBUS DP
NCU 7x0.3 PN
Manual, 09/2011, 6FC5397-1EP40-0BA0
61
Station name Module type Interface IP address
X120 192.168.200.1 NCU 730.3 PN
X150 port 1 192.168.200.2
PCU 50.3 X501 192.168.200.5
Central
MPP 483 IE X20 DHCP server 192.168.200.50
X120 192.168.200.11 Unit01 NCU 730.3 PN
X150 port 1 192.168.200.12
Unit02 CPU 319-3 PN/DP PN P1 192.168.200.22
Unit03 CPU 317-2 PN/DP PN P1 192.168.200.32
7.8 PROFIBUS DP
7.8.1 Application
Connectable devices
The following devices can be connected to the PROFIBUS DP interfaces:
Distributed I/O
Drive units with PROFIBUS DP interface (standard slaves)
S7 controllers with PROFIBUS DP interface
PG/PC
Note
Isochronous operation with PROFIBUS DP for the NCU is only possible at the line of
terminal X126. Only signals from the PLC I/Os can be evaluated on the line of terminal
X136.
Properties
Isolated RS 485 interface
Max. data rate 12 Mbaud
Supports master/slave operation
PROFIBUS address is set via configuration
Note
In addition to the DP (distributed I/O) protocol, X136 can also transmit the MPI (multi
point interface) protocol (software-controlled).