Connecting
7.6 Use of Ethernet interfaces
NCU 7x0.3 PN
52 Manual, 09/2011, 6FC5397-1EP40-0BA0
7.6 Use of Ethernet interfaces
Application
The following connections can be established via the Ethernet interfaces:
X120 provides the link to the system network (e.g. operator panels).
X130 connects the Control Unit to the company network.
X127 is used for commissioning and remote diagnostics via teleservice adapter IE.
You can find further details in the following manuals:
SINUMERIK 840D sl Basesoftware and Operating Software Commissioning Manual
SIMATIC TS Adapter IE Manual
Properties
The interfaces are full duplex 10/100/1000 Mbit Ethernet ports. Both ports are connected as
an Ethernet terminal.
Pin assignment
Table 7- 9 Ethernet interfaces X120, X130, X127 in the 10/100 Mbit mode
Pin Signal name Signal type Meaning
1 TXP B Transmit data +
2 TXN B Transmit data -
3 RXP B Receive data +
4 - - Reserved, do not use
5 - - Reserved, do not use
6 RXN B Receive data -
7 - - Reserved, do not use
8 - - Reserved, do not use
Signal type: B = bidirectional