7.5.2 Connectable DRIVE-CLiQ components
Components
As a rule, all SINAMICS components approved for SINUMERIK can be connected using the
DRIVE-CLiQ interface.
Table 7- 8 Components with DRIVE-CLiQ
Component Description
NX10/15 Drive expansion module for up to 6 axes
SINAMICS S120, system components of the booksize and chassis formats
Smart / Active / Basic
Line Module
Line Modules provide the central power supply to the DC link.
Single / Double Motor
Module
Motor Modules draw their power from the DC link to supply the
connected motors.
SINAMICS S120 Combi (only in connection with NCU 710.3)
Power Module Integrated infeed, Motor Modules for 3 or 4 axs and TTL encoder
evaluation for the spindle.
Motor Module Booksize
Compact
Expansion axes for Power Modules.
SINAMICS S120, additional system components
SMC10/20/30 Cabinet-Mounted Sensor Modules are needed when a motor with a
DRIVE-CLiQ interface is not available and when external encoders
are required in addition to the motor encoder.
SME20/25 Measuring systems outside the cabinet can be connected directly to
the Sensor Module External.
DMC20/DME20 DRIVE-CLiQ Hub Modules are used to implement star-shaped
distribution of a DRIVE-CLiQ line.
TM15 The number of available digital inputs and outputs within a drive
system can be expanded with the TM15 Terminal Module.
TM120 The TM120 Terminal Module is used for temperature evaluation with
protective separation. It can be used for 1FN, 1FW6 and third-party
motors.
Further references for SINAMICS S120 components
● You can find information about Line Modules and Motor Modules in:
– Equipment Manual Booksize Power Units
– Chassis Power Units Equipment Manual
● Information on the Power Modules and Motor Modules Booksize Compact can be found
in the "Manual SINAMICS S120 Combi".
● You can find information on all other modules in "Manual Control Units and
supplementary system components".