Connectable components
9.1 NX10.3 / NX15.3
NCU 7x0.3 PN
90 Manual, 09/2011, 6FC5397-1EP40-0BA0
The following figure shows a sample topology:
([WHUQDO352),%86'3'3
6XEWRSRORJ\1;
6XEWRSRORJ\1;
'3DGGUHVV
'5,9(&/L4FRPSRQHQWVRQWKH1&8
'3DGGUHVV
(7
1&8
1;
1;
;
;
;

;
;

;
;

;
Figure 9-5 NX topology
X122 digital inputs/outputs
When commissioning the drive wizard, the digital inputs/outputs are correspondingly
preassigned functions.
For more information about terminal assignment, see:
The "Communication in the system" section of the "Machine Configuration Guidelines"
System Manual
The "IBN CNC: NCK, PLC, Drive" Commissioning Manual, "Tips" chapter
Table 9- 7 Interface characteristics of X122
Characteristics Version
Connector type Spring-loaded terminals
Connection option 0.2 to 1.5 mm
2
Stripped length 8 mm
Max. current carrying capacity 6 A