PROGRAMMING | 95
M93 SPARE M-CODE EXTERNAL M93 COMMAND
M94 SPARE M-CODE EXTERNAL M94 COMMAND
Function
M-code in reserve. Output port is reserved.
When commanding M91, if a relevant output becomes "ON" and relevant input is
responded, M-code is completed.
When commanding M92, if a relevant output becomes "ON" and relevant input is
responded, M-code is completed.
Regarding M93, relevant output becomes "ON" and time set in TM19 passed by, M-
code is completed.
Regarding M94, relevant output becomes "ON" and time set in TM20 passed by, M-
code is completed.
M121 CENTER COOLANT A ON
Operate Center coolant connected to the port A located under the tool post.
This M-code valid only VT1100 machine.
Function
Center coolant A operate in case of Splash Guard, Shutter door close and
coolant on switch selected condition by M-code command.
Center coolant A operation is stopped this following command.
- Others center coolant command by M-code
- Center coolant Off command by M124