96 | Part 3
■ M122 CENTER COOLANT B ON
Operate Center coolant connected to the port B located under the tool post.
This M-code valid only VT1100 machine.
• Function
Center coolant B operate in case of Splash Guard, Shutter door close and
coolant on switch selected condition by M-code command.
Center coolant B operation is stopped this following command.
- Others center coolant command by M-code
- Center coolant Off command by M124
■ M123 CENTER COOLANT B ON
Operate Center coolant connected to the port C located under the tool post.
This M-code valid only VT1100 machine.
• Function
Center coolant C operate in case of Splash Guard, Shutter door close and
coolant on switch selected condition by M-code command.
Center coolant C operation is stopped this following command.
- Others center coolant command by M-code
- Center coolant Off command by M124
■ M124 CENTER COOLANT OFF
• Function
Stop Center Coolant connected each port at the under tool post.
■ M126 STRADDLE TOOL CLAMP
• Function
Clamp Straddle Tool.
• Completion of Command
M-code will be finished after the time set in TM38(TM138) passed by.
• Condition of Function
In the case that straddle tool is used, the machine is Gang Type and alarm
relating to T-code, Tool does work.