6/49 2015-02-27 CE1G2201xx
Mounting notes REV13..
1 Placement of unit
· The REV13.. should be mounted in the main living room (for
wall mounting, refer to Figs. B through E)
· The REV13.. must be located such that it can acquire the
room temperature as accurately as possible, without getting
affected by direct solar radiation or other heat or refrigeration
sources
min.
10 cm
2261Z03
2 Mounting
· Refer to Figs. A through E
3 Checking the wiring
For electrical connections, refer to “Connection diagram”.
Note: Do not use stranded wires, only solid wires
or stranded wires with ferrules!
4 Notes
· The local regulations for electrical installations must be
complied with
· If the reference room is equipped with thermostatic radiator
valves, they must be set to their fully open position
· External preliminary protection with max. C 10 A circuit
breaker is required in all cases
Commissioning
1 Switching on the REV13..
· Remove the black battery transit tab (Fig. F); as soon as the
tab is removed, the unit is ready to operate (also refer to
operating instructions)
2 Selecting the language
· When starting up, the display shows the type of controller at
top left and “THANK YOU …“ in all available languages on the
text line
· Press one of the buttons to stop the running display. The
choice of languages starts with “ENGLISH(factory setting).
Press
or until the language you require appears.
Press
or move the slider to confirm the selected language
(also refer to Fig. G)
Configuration and function check REV13..
1 Configuration
1.1 DIP switches
ON / OFF 1 2 3 4 5 6
See
1.1.1
Sensor calibration on
Sensor calibration off
1.1.2
Setpoint limitation 16…35 °C
Setpoint limitation 3…35 °C
1.1.3
Temperature display °F
Temperature display °C
1.1.4
PID self-learning
PID 6
PID12
2-Point
1.1.5
Quartz
Radio clock
1.1.6
DIP switch reset
ON
1 342
2211Z32
567 89
When changing one or several DIP switch positions, a DIP switch reset must be made by
pressing the DIP switch reset button (also refer to Fig.
).
Otherwise, the previous settings will be maintained!
Factory setting: All DIP switches
OFF
DE
EN
FR
IT
NL
ES
PT
CS
HU
PL
SV
FI
DA
TR
EL