Technical Specifications
5.4Fiber Optic Ethernet Port Specifications
Isolation
e
1.5 kV
a
Auto-negotiating.
b
Shielded or unshielded.
c
Auto-crossover and auto-polarity.
d
Typical distance. Dependent on the number of connectors and splices.
e
RMS 1 minute.
5.4 Fiber Optic Ethernet Port Specifications
The following details the specifications for fiber optic Ethernet ports that can be
ordered with the RUGGEDCOM RS8000T.
5.5 Operating Environment
The RUGGEDCOM RS8000T is rated to operate under the following environmental
conditions.
Ambient Operating
Temperature
a
-40 to 85°C (-40 to 185 °F)
Ambient Storage
Temperature
-40 to 85°C (-40 to 185 °F)
Ambient Relative
Humidity
b
5% to 95%
Maximum Altitude 2000 m (6562 ft)
a
Ambient Temperature as measured from a 30 cm radius surrounding the center of the enclosure.
b
Non-condensing
5.6 Mechanical Specifications
Weight 2.25 kg (5 lbs)
Ingress Protection IP30
Enclosure 18 AWG Galvanized Steel
5.7 Dimension Drawings
Note
All dimensions are in millimeters, unless otherwise stated.
22
RUGGEDCOM RS8000T
Installation Manual, 01/2021, C79000-G8976-1023-05

Other manuals for Siemens RUGGEDCOM RS8000T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens RUGGEDCOM RS8000T and is the answer not in the manual?

Siemens RUGGEDCOM RS8000T Specifications

General IconGeneral
BrandSiemens
ModelRUGGEDCOM RS8000T
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals