Programming the program blocks
5.4 IF_CONF: SDT for the configuration data of the CP
CP 1243-7 LTE
104 Operating Instructions, 01/2015, C79000-G8976-C381-01
"Preferred mobile wireless networks"
In STEP 7, the corresponding data is located in the "Mobile wireless communications
settings" parameter area.
Table 5- 9 IF_CONF_PrefProvider
Parameter
Data type
Initial value
Description
Id
UINT
14
ID of the parameter field
Length UINT Length of the parameter field in bytes: 46
Mode
UINT
Validity (1, 2) - see above (general parameters)
Provider [1...5] ARRAY [1...5]
of STRING [6]
Alternative mobile wireless networks with priority 1 to 5
into which the CP dials. Up to 5 networks can be config-
ured. No. 1 with highest priority, no. 5 with lowest priority.
Entry of the Public Land Mobile Network (PLMN) of the
network provider consisting of Mobile Country Code
(MCC) and Mobile Network Code (MNC).
Example (test network of Siemens AG): 26276
TeleService access (DNS name / IP address of the server)
Access data of the TeleService server (switching station).
In STEP 7, the corresponding data is located in the "Mobile wireless communications
settings" parameter area.
Table 5- 10 IF_CONF_TS_Name
Parameter
Data type
Initial value
Description
Id
UINT
20
ID of the parameter field
Length
UINT
Length of the parameter field in bytes: 266
Mode
UINT
Validity (1, 2) - see above (general parameters)
ts_name String [254] Name of the TeleService server that can be resolved by
DNS or IP address as string
RemotePort
UINT
Port of the engineering station
Rank UINT Priority of the server [1] or [2]:
1 = server 1
2 = server 2 (not relevant)