Security recommendations
SCALANCE W760/W720
Operating Instructions, 07/2020, C79000-G8976-C322-12
11
Service
Protocol/port num-
ber
Default port
status
Configurable
Authentication
Encryption
Port
Service
SSH
TCP/22
Open
Syslog Client
UDP/514
Closed
--
--
Syslog (secure) Client
TCP/6514
Closed
--
Telnet
TCP/23
Open
--
TFTP client UDP/69 Closed -- --
DCP
--
Open
--
--
--
LLDP
--
Open
--
--
--
RSTP
--
Open
--
--
--
iPRP
--
Open
--
--
--
MSTP
--
Closed
--
--
--
IPv6
--
Closed
--
--
--
SIMATIC NET TIME
--
Closed
--
--
--