PROFINET IO functionality
6.4 Data record 0x802A (PDPortDataReal)
SCALANCE X-300 / X-400
348 Configuration Manual, 10/2014, C79000-G8976-C187-22
PeerChassisID
ID of the neighboring device.
LineDelay
LineDelay.FormatIndicator = 0
Value (hexadecimal)
Meaning
0x00000000
Line delay and cable delay unknown.
0x00000001 0x7FFFFFFF
Line delay in nanoseconds.
LineDelay.FormatIndicator = 1
Value (hexadecimal)
Meaning
0x00000000
Reserved
0x00000001 0x7FFFFFFF Cable delay in nanoseconds.
PeerMACAddress
MAC address of the neighboring device.
MAUType
Value (hexadecimal)
Meaning
0x0000 0x0004
Reserved
0x0005
10BASET
0x0006-0x0009
Reserved
0x000A
10BASETXHD
0x000B
10BASETXFD
0x000C
10BASEFLHD
0x000D
10BASEFLFD
0x000F
100BASETXHD
0x0010
100BASETXFD (default)
0x0011
100BASEFXHD
0x0012
100BASEFXFD
0x0013 0x0014
Reserved
0x0015
1000BASEXHD
0x0016
1000BASEXFD
0x0017
1000BASELXHD
0x0018
1000BASELXFD
0x0019
1000BASESXHD
0x001A
1000BASESXFD
0x001B 0x001C Reserved
0x001D
1000BASETHD