3.4 Parameterization
7KT multimeter
24 Manual, 08/2018, 2514284149-01
5. Select the submenu and the serial parameter number as appropriate.
Use the keys as follows:
: Back
: Decrease
: Increase
: Next
6. After setting the required parameter number, use the key to switch to edit mode. The
parameter appears in the alphanumeric display.
Use the keys as follows:
Press or : To change the parameter within the permissible range.
Press and simultaneously: To set the minimum possible value.
Press and simultaneously: To set the maximum possible value.
Press and simultaneously: To restore the factory default value.
The required value is selected.
7. Press to save the parameter.
The display returns to the previous menu level (parameter selection).
8. Press repeatedly to leave and save the parameters.
Note
Alternatively, you can hold down
for 3 seconds during programming to save the
changes and exit parameter settings directly.
The device is rebooted.
Note
If you do not press any key for a period
of 2 minutes, the system exits the setup menu and
returns to the standard display without saving the parameters.