8.4 Mechanical ambient conditions 
  Comfort Panels 
190  Operating Instructions, 07/2017, A5E36770603-AB 
Emission of radio interference  
The following table shows the emitted interference from electromagnetic fields according to 
EN 61000-6-4, measured at a distance of 10 m. 
 
From 30 to 230 MHz  < 40 dB (μV/m) quasi-peak 
< 47 dB (μV/m) quasi-peak 
Notes about usage (Page 30) 
 
Mechanical ambient conditions 
8.4.1
 
The following information is for a device that is transported and stored in its original 
packaging.  
The device meets the requirements according to IEC 60721-3-2 Class 2M2 with the following 
amendments and limitations: 
 
Free fall  ≤ 1 m 
Vibration according to IEC 60068-2-6  5 .. 8.4 Hz, deflection 3.5 mm 
8.4 ... 500 Hz, acceleration 1 g 
Shock according to IEC 60068-2-27 
2
 
The following information applies to a device installed according to the specifications in these 
operating instructions. 
The device was tested based on IEC 60721-3-3 Class 3M3 with the following amendments 
and limitations: 
 
Vibration according to IEC 60068-2-6  5 ... 8.4 Hz, deflection 3.5 mm 
8.4 ... 150 Hz, acceleration 1 g 
Shock according to IEC 60068-2-27 
2
Shock pulses within the specified range can be transferred to the display but do not impact 
the functionality of the device.