The HMI device is designed for stationary operation in a location protected from the effects 
of the weather. 
The device meets the requirements according to IEC 60721-3-3, Class 3K3 with the 
following amendments and limitations: 
 
Permitted position, permitted range 
Temperature, mounting in 
landscape format 
Inclined, maximum inclination 35°  0 ... 40 °C 
Temperature, mounting in 
portrait format 
Vertical  0 ... 40 °C 
Inclined, maximum inclination 35° 
1080 ... 795 hPa, corresponds to an elevation of -1000 to 2000 m 
10 ... 90%, without condensation 
Pollutant concentration  SO2: < 0.5 ppm; relative humidity < 60%, no condensation 
H
2
S: < 0.1 ppm; relative humidity < 60%, no condensation 
 
The diagram below shows the extended range for temperature and humidity during 
continuous operation based on IEC 60721-3-3 Class 3K3.  
The information applies to a device installed in landscape without inclination.