B-4
Equipment
Manual OP7, OP17
Release 04/99
Remedy:CauseMes-
sage
109 Restart
after change of operating mode from of
-
fline to online.
110,
113
OP is in ”normal” mode.
114
PLC has been restarted.
115
Establishment of logical link with PLC in pro
-
gress.
117
Connection with PLC is OK again following a
fault.
119
Automatic restart.
120
Restart after change of S5 protocol.
124
Restart following selection of dif
ferent language.
129
SINEC L1 or SINEC L2 parameter has been
changed
130,
132
Startup due to loop-through operation when
online.
134
Restart due to of
fline operation.
136
PLC not responding.
Check program sequence on PLC.
Check physical connection.
138
Data block not available on PLC
Set up relevant memory area.
201
Hardware fault on timer module.
Send unit for repair
.
202
Error reading date
Send unit for repair
.
203
Error reading time
Send unit for repair
.
204
Error reading day
Send unit for repair
.
205
Printer not ready and internal storage of print jobs
is no longer possible.
Make sure printer is ready or disable
message logging.
206
Printer not ready
. Print job placed in temporary
storage.
Make sure printer is ready
.
207 Buf
fer printout or print screen function cancelled.
Check printer
, cable and connectors.
210
Internal err
or
OP co-ordination area not receivable during star
-
tup.
Press restart button.
212
Internal err
or
Bit for changing operating mode has been inver
-
ted erroneously
.
Restart OP
.
213 Of
fline mode not possible at present.
T
ry change of operating mode again
later.
214
The job number sent by the PLC or configured in
a function field is too lar
ge.
Check PLC program and configured
screen.