B-6
Equipment
Manual OP7, OP17
Release 04/99
Remedy:CauseMes-
sage
314 S7
diagnostics buf
fer not present.
The CPU has no diagnostics buf
fer
(hardware problem).
315
No information text available.
317
Input is password protected.
Enter password.
318
Incorrect password entered when attempting to
log in.
319
An existing password was entered when editing
the password.
Enter a dif
ferent password.
320 Y
ou have attempted to alter the level of or delete
the supervisor password.
321 Y
ou have attempted to alter the level of an invalid
password.
First enter the password then specify
the level.
322
The password entered is too short.
Password must be at least three cha
-
racters long.
323 Y
ou have pressed <– Statistics or Message T
ext
–> on a buf
fer screen but there is no entry for the
current message.
––
324
The entry number specified does not exist on the
selected screen.
––
325
The FM/NC (= MPI peer) has no alarm messages
buffer.
A node does not have the required
functional capability
.
326 Y
ou have attempted to collect a recipe number
other than the active recipe number from the
PLC.
Select the appropriate recipe number
.
327
There is no recipe number when a recipe is selec
-
ted.
Configure missing recipe or select a
dif
ferent one.
328
Recipe number >99 when selecting a recipe.
329
The same number has been entered for source and
destination on the ”Data Record T
ransfer” screen.
Enter dif
fering numbers.
330
Full details of source and destination not entered
when initiating data record transfer function.
331
The data record specified as the source does not
exist.
332
Data record number >99 when selecting a recipe
screen.
333
Data record number not present when selecting a
recipe screen.
335
Information message: alarm message will be sup
-
pressed.
336
No process screens have been configured.
337
No recipes have been configured.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens simatic hmi op7 and is the answer not in the manual?

Siemens simatic hmi op7 Specifications

General IconGeneral
BrandSiemens
Modelsimatic hmi op7
CategoryControl Panel
LanguageEnglish

Related product manuals