Software and commissioning
4.2 Install example image on eMMC
SIMATIC IOT2050
44 Operating Instructions, 03/2024, A5E39456816-AF
8. Enter "root" after "login as" and then enter the password for "root".
You will be prompted to change the root password the first time you log in. Change the
password when prompted.
9. Now you can test some Linux commands.
4.2.3.4 Setting up network interface
The IP address on SIMATIC IOT2050's default image is set as 192.168.200.1. Therefore, if a
DHCP address or another static IP address is needed, you can configure it using the "nmtui".
Set the IP address of IOT2050
1. Open a serial Putty connection and log in as root.
2. Enter "nmtui" to open the network manager tool.
3. Navigate to the "Activate a connection" and press Enter.
4. Select the interfaces you want to enable.
For V1.0.1, select "eth0" and "eth1"
For V1.1.1, select "eno1" and "eno2"
Note: eth0 and eno1 are enabled by default, while eth1 and eno2 is disabled by default.
However, eth1 and eno2 are automatically enabled when a LAB cable is connected.

Table of Contents

Other manuals for Siemens SIMATIC IOT2050

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC IOT2050 and is the answer not in the manual?

Siemens SIMATIC IOT2050 Specifications

General IconGeneral
Storage8 GB eMMC
Real-time clockYes, with battery backup
RAM1 GB DDR3L
Interfaces2 x Ethernet, 2 x USB
Operating SystemLinux-based
Power Supply24V DC
CertificationsCE, UL, FCC
Operating Temperature0°C to 50°C