Page #120 background image
Configuring with Web Based Management
4.4 "System" menu
SCALANCE SC-600 Web Based Management (WBM)
120 Configuration Manual, 10/2021, C79000-G8976-C475-03
SSH key exchange algorithm level
Configure the level of SSH key exchange algorithm for SSH access to the CLI.
High (default)
Curve25519-sha256
Curve25519-sha256@libssh.org
Ecdh-sha2-nistp256
Ecdh-sha2-nistp384
Ecdh-sha2-nistp521
Diffie-hellman-group16-sha512
Diffie-hellman-group18-sha512
Low
Curve25519-sha256
Curve25519-sha256@libssh.org
Ecdh-sha2-nistp256
Ecdh-sha2-nistp384
Ecdh-sha2-nistp521
Diffie-hellman-group16-sha512
Diffie-hellman-group18-sha512
Diffie-hellman-group14-sha256
Diffie-hellman-group14-sha1
HTTP Server
Enable or disable HTTP access to the WBM.
HTTP Port
Specify the port for HTTP access to the WBM.
HTTPS Server
Enable or disable HTTP access to the WBM.
HTTPS Port
Specify the port for HTTPS access to the WBM.
HTTP Services
Specify how the WBM is accessed:
HTTPS
Access to the WBM is only possible with HTTPS.
Redirect HTTP to HTTPS
Access via HTTP is automatically diverted to HTTPS.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE SC622-2C and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE SC622-2C Specifications

General IconGeneral
Product Type DesignationSCALANCE SC622-2C
Number of SFP Ports2
Power Supply24 V DC
Operating Temperature-40 to +70 °C
Mounting TypeDIN Rail
Protection ClassIP30
MAC Address Table8000 entries
Weight500 g
StandardsIEEE 802.3, IEEE 802.3u