Page #313 background image
Configuring with Web Based Management
4.7 "Security" menu
SCALANCE SC-600 Web Based Management (WBM)
Configuration Manual, 10/2021, C79000-G8976-C475-03
313
4.7.5.4 IP services
On this WBM page, you define IP services. Using the IP service definitions, you can
define firewall rules for specific services. You select a name and assign the service
parameters to it. When you configure the IP rules, you simply use this name.
Description
The page contains the following:
Service Name
Enter the name of the IP service. The name must be unique.
This table contains the following columns:
Select
Activate the check box in the row to be deleted.
Service Name
Shows the name of the IP service.
Transport
Specify the protocol type.
UDP
The rule applies only to UDP frames.
TCP
The rule applies only to TCP frames.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE SC622-2C and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE SC622-2C Specifications

General IconGeneral
Product Type DesignationSCALANCE SC622-2C
Number of SFP Ports2
Power Supply24 V DC
Operating Temperature-40 to +70 °C
Mounting TypeDIN Rail
Protection ClassIP30
MAC Address Table8000 entries
Weight500 g
StandardsIEEE 802.3, IEEE 802.3u