Configuring with Web Based Management
4.4 "System" menu
SCALANCE SC-600 Web Based Management (WBM)
Configuration Manual, 10/2021, C79000-G8976-C475-03
197
4.4.12 Button
Functionality
The SET button is used for:
• Resetting to factory settings.
• Defining the fault mask and the LED display.
You will find a detailed description of the functions in the operating instructions for the
device.
On this page, the functionality of the button can be restricted.
Description
The following functionality is possible:
• Restore Factory Defaults
When disabled, the SET button cannot be used to restore factory defaults.
CAUTION
Button function "Restore Factory Defaults" active during startup
If you have disabled this function in your configuration, disabling is only valid during
operation. When restarting, for example after power down, the function is active
until the configuration is loaded so that the device can inadvertently be reset to the
factory settings. This may cause unwanted disruption in network operation since the
device then needs to be reconfigured. An inserted PLUG is also deleted and
returned to the status as shipped.
• Set Fault Mask
Enable or disable the function "Define fault mask via the LED display" with the
SELECT/SET button.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE SC622-2C and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE SC622-2C Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE SC622-2C
CategorySwitch
LanguageEnglish

Related product manuals