EasyManuals Logo

Siemens SIMATIC NET SCALANCE SC622-2C User Manual

Siemens SIMATIC NET SCALANCE SC622-2C
372 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #297 background image
Configuring with Web Based Management
4.7 "Security" menu
SCALANCE SC-600 Web Based Management (WBM)
Configuration Manual, 10/2021, C79000-G8976-C475-03
297
Modifying servers
1. In the relevant row, enter the following data in the input boxes:
RADIUS Server Address
Server Port
Shared Secret
Shared Secret Conf
Max. Retrans.
Primary Server
2. If necessary check the reachability of the RADIUS server.
3. Click the "Set Values" button.
Repeat this procedure for every server whose entry you want to modify.
Deleting servers
1. Click the check box in the first column before the row you want to delete to select the
entry for deletion.
Repeat this for all entries you want to delete.
2. Click the "Delete" button. The data is deleted from the memory of the device and the
page is updated.
4.7.3.3 802.1X Authenticator
Setting up network access
An end device can only access the network after the device has verified the login data of
the device with the authentication server. The authentication can be via 802.1X or the
MAC address.
When authenticating using 802.1X both the end device and the authentication server
must support the EAP protocol (Extensive Authentication Protocol).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE SC622-2C and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE SC622-2C Specifications

General IconGeneral
Product Type DesignationSCALANCE SC622-2C
Number of SFP Ports2
Power Supply24 V DC
Operating Temperature-40 to +70 °C
Mounting TypeDIN Rail
Protection ClassIP30
MAC Address Table8000 entries
Weight500 g
StandardsIEEE 802.3, IEEE 802.3u

Related product manuals