Security recommendations
SCALANCE SC-600 Web Based Management (WBM)
22 Configuration Manual, 10/2021, C79000-G8976-C475-03
Service/Protocol
Protocol/
Default status
Configurable
Authenticati
Encryption
SMTP Client
TCP/25
Outgoing
only
Outgoing only
Optional
--
SMTP (secure)
TCP/465
TCP/587
Outgoing
only
Outgoing only
Optional
SNMPv1/v2c
UDP/161
Open
Closed
--
--
SNMPv3
UDP/161
Open
Closed
Optional
Optional
SNMP Traps
UDP/162
Outgoing
only
Outgoing only
--
--
SNTP Client
UDP/123
Closed
Closed
--
--
SSH
SFTP
TCP/22
Open
Closed
Syslog Client
UDP/514
Outgoing
only
Outgoing only
--
--
Syslog Client TLS
TCP/6514
Outgoing
only
Outgoing only
--
TFTP
UDP/69
Outgoing
only
Outgoing only
--
--
VRRP
IP/112
Closed
Closed
--
--
--
*)
Depending on the device type, VLAN1 and VLAN2 are on different physical ports:
SC6x2
-2C: VLAN1 = port 1, VLAN2 = port 2
SC6x6-2C: VLAN1 = port 1-4, VLAN2 = port 5-6
Layer 2 services
Default status
Configurable
DCP
Open (when configured)
LLDP
Open (when configured)
SIMATIC NET TIME
Open (when configured)
VLAN
Open (when configured)