EasyManua.ls Logo

Siemens SIMATIC OEM PP32 - Page 53

Siemens SIMATIC OEM PP32
69 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
A-3
OEM
Push Button Panel Equipment Manual
Release 08/98
OEM PP32/OP17OEM PP3224 V digital inputs
Input current with signal “1” Typ. 5 mA at 24 V
Time delay of imputs 0.3 ms
Bouncing time v 10 ms
Maximum cable length
S with unshielded cable
s
S with shielded cables
1 m
> 1 m
24 V Digital outputs OEM PP32 OEM PP32/OP17
Number of outputs
S in groups of
S output DO1 to DO4
S output DO5 to DO8
S output DO9 to DO12
S output DO13 to DO16
16
4
Group 1
Group 2
Group 3
Group 4
Potential isolation
Short circuit protection Yes
Permissible loads
Resistive
Lamps
Inductive
Max. inductive power 200 mWs
Output voltage
S with signal “0”
S with signal “1”
Max. 2 V (idling)
Min. voltage supply -3 V
Output current
S with signal “0”
S with signal “1”
Max. 1 mA
Max. 500 mA per group;
1 output 200 mA
and the others 100 mA
Switching frequency with
S resistive load
S lamp load
S inductive load
Max. 100 Hz
Max. 8 Hz
Max. 0.5 Hz
Technical Data