4
Getting Started Rack PC 840
A5E00104828-04
Recording the Serial Number and the Ethernet address
6. Enter the serial number (S VP) and the Ethernet address of your PC in the table below. You can
find the serial number on the type label attached to the rear of the device. The Ethernet address
can be found in the BIOS setup settings in the main menu under the ’Hardware Options’ function.
The device can precisely be identified with the help of these numbers in case of repairs or theft.
Enter the Microsoft Windows “Product Key” from the “Certificate of Authenticity”
7. Enter the Microsoft Windows “Product Key” from the “Certificate of Authenticity” (COA) in the
table. You will find the “Product Key” on the inside of the front door. You need the Windows
“Product Key” if you want to reinstall the operating system.
Serial number S VP...
Order No. 6ES...
Microsoft Windows Product Key
Ethernet Address
+ Installing the Rack PC
The Rack PC is particularly suitable for horizontal fitting in consoles, switch boards and 19” rack
systems.
The Rack PC with AC power supply meets the requirements for a fire enclosure to EN60950. it can
therefore be fitted without an additional fire enclosure.
The Rack PC with DC power supply does not fulfil the power supply connection requirements for a
fire enclosure. Therefore, the device has to be installed in a fire enclosure in such a way that the
device front can remain accessible as it fulfills the fire enclosure requirements according to UL 508.
!
Warning
Only connect the device to 24V DC power supply systems which meet the requirements of a safe
extra-low voltage (SELV); in addition, a protective conductor must be connected.
The cable cross section has to be large enough that the Rack PC will not be damaged by the
cables when there is a short circuit.
Please note the following points when installing the PC:
• Avoid extreme ambient conditions as far as possible. Protect your PC from dust, moisture, and
heat.
• Keep the PC out of direct sunlight.
• Mount the PC as safely as possible to prevent any danger (for example, by falling over).
• The clearance near the ventilation slots must be at least 50 mm, so that the PC is sufficiently
ventilated.
• Make certain that the ventilation slots for the housing are not covered.
• The device is meets the protection class IP41 requirements on the front side. Ensure that opening
for the Rack PC is protected against water in an environment where there is a risk of splashing
water.
• Make certain that the sliding door in front of the drives is closed during operation.
• The Rack PC can be mounted on telescopic rails or on cabinet brackets. It is not permitted to
mount it at the 19” front supports only.