4011-3XXXSIMATIC IPC RW-543A
SIMATIC
Industrial PC
SIMATIC IPC RW
-543A
Operating Instructions
03/2023
A5E52332059
-AA
Preface
Product description
1
Safety instructions
2
Installing and connecting
the device
3
Commissioning the device
4
Operating the device
5
Expanding and assigning
parameters to the device
6
Device maintenance and
repair
7
Technical specifications
8
Dimension drawings
9
Standards and approvals
10
BIOS description
11
Hardware description
A
Technical support
B
Markings and symbols
C
List of abbreviations
D

Table of Contents

Questions and Answers

  • K
    Kristine WilliamsAug 11, 2025
    What to do if my Siemens SIMATIC IPC RW-543A is not operational?
    • J
      John PhillipsAug 11, 2025
      If your Siemens Industrial PC is not operational, first check the power supply, power cable, and power plug to ensure they are correctly connected. Also, verify that the on-off switch is in the correct position. If the issue persists, ensure the device is operating within the specified ambient conditions. If the device was transported in cold weather, allow a waiting period of approximately 12 hours before turning it on.
  • G
    gbensonAug 19, 2025
    What to do if the monitor remains dark on my Siemens SIMATIC IPC RW-543A?
    • J
      john27Aug 19, 2025
      If the monitor of your Siemens Industrial PC remains dark, first ensure the monitor is switched on and not in 'power save' mode by pressing any key on the keyboard. Check the brightness button to ensure it hasn't been set too low. Also, verify that the power cord is properly connected to the monitor and the system unit or a grounded shockproof power outlet, and that the monitor cable is securely connected to both the system unit and the monitor.
  • S
    Sandra PaulAug 27, 2025
    What to do if the mouse pointer does not appear on the screen of my Siemens SIMATIC IPC RW-543A?
    • B
      Brian RomeroAug 27, 2025
      If the mouse pointer does not appear on the screen of your Siemens Industrial PC, check whether the mouse driver is properly installed and available when you start the user program. Also, ensure that the mouse cable is properly connected to the system unit. If you are using an adapter or extension cable, check these connections as well.
  • B
    Brittany GreenSep 3, 2025
    Why are the time and date wrong on my Siemens Industrial PC even after setting them in the firmware (BIOS)?
    • A
      Andrew NixonSep 3, 2025
      If the time and date are wrong on your Siemens Industrial PC even after correctly setting them in the firmware (BIOS), the backup battery is likely dead. Replace the backup battery to resolve this issue.

Siemens SIMATIC IPC RW-543A Specifications

General IconGeneral
Type of deviceIndustrial PC
Operating SystemWindows 10 IoT Enterprise
Ethernet2 x Gigabit Ethernet
Power Supply24 V DC
Temperature Range0 to 50°C
Serial Ports2 x RS-232/422/485
Weight2.5 kg
Protection ClassIP20
ConnectivityWi-Fi, Bluetooth
USB4 x USB 3.0
Video1 x DisplayPort
DisplayNo display