EasyManua.ls Logo

Siemens Simatic IPC647C - User Manual

Siemens Simatic IPC647C
246 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
SIMATIC IPC647C
_
_________________
_
_
_________________
_
_
_________________
_
_
_________________
_
_
_________________
_
_
_________________
_
_
_________________
_
_
_________________
_
_
_________________
_
_
_________________
_
_
_________________
_
_
_________________
_
_
___________
_
______
_
_________________
_
_
_________________
_
_
_________________
_
_
_________________
_
_
_________________
_
_
_________________
_
SIMATIC
Industrial PC
SIMATIC IPC647C
Operating Instructions
12/2010
A5E02669337-02
Introduction
1
Safety notes
2
Description
3
Application planning
4
Installing
5
Connecting
6
Commissioning
7
Integration into an
automation system
8
Functions
9
Expansions and parameter
assignment
10
Service and maintenance
11
Alarm, error, and system
messages
12
Troubleshooting/FAQs
13
Technical specifications
14
Dimension drawings
15
Detailed descriptions
16
Appendix
A
ESD guidelines
B
List of abbreviations
C

Table of Contents

Other manuals for Siemens Simatic IPC647C

Questions and Answers

  • D
    Dawn BurgessAug 16, 2025
    What to do if my Siemens Simatic IPC647C Industrial PC does not boot or shows 'Boot device not found'?
    • S
      steven82Aug 16, 2025
      If your Siemens Industrial PC doesn't boot or displays 'Boot device not found', it's likely that the boot device isn't the top priority in the BIOS setup or is excluded. To fix this, go to the Boot menu in the BIOS setup and change the boot priority of the boot device, or include the device in the boot priority.
  • L
    Lisa HallAug 19, 2025
    Why is the external monitor dark on my Siemens Simatic IPC647C?
    • C
      Craig McmillanAug 19, 2025
      If the external monitor remains dark when using your Siemens Industrial PC, first ensure that the monitor is switched on. If it is, check if it's in 'power save' mode and press any key on the keyboard. Also, verify that the luminance control isn't set too low; increase the brightness. Finally, make sure both the power cord and monitor cable are properly connected to the system unit, the monitor, and a grounded outlet.
  • R
    Ryan SchwartzAug 22, 2025
    How to troubleshoot a Siemens Simatic IPC647C that is not operational?
    • C
      Charlene AndersonAug 22, 2025
      If your Siemens Industrial PC is not operational, start by checking the power supply and ensure the power cord and connector are properly connected. Also, verify that the device is operating within the specified environmental conditions. If the device was shipped in cold weather, wait approximately 12 hours before switching it on.
  • J
    Joseph LittleAug 25, 2025
    What to do if a USB device is not responding on Siemens Simatic IPC647C?
    • S
      Suzanne MartinezAug 26, 2025
      If a USB device is not responding on your Siemens Industrial PC, try using a different USB port or enabling the port in the BIOS settings. If you're using a USB 2.0 device, make sure USB 2.0 is enabled in the BIOS.
  • C
    Chelsea WilliamsAug 28, 2025
    Why doesn't the mouse pointer appear on my Siemens Industrial PC?
    • C
      Craig BoyleAug 28, 2025
      If the mouse pointer does not appear on the screen of your Siemens Industrial PC, ensure the mouse driver is properly installed and present when you start the application program. Also, check whether the mouse cord is properly connected to the system unit and that any adapters or extensions on the mouse cable are securely connected.
  • K
    Kristin MendezAug 31, 2025
    Why does the screen flicker on my Siemens Industrial PC?
    • B
      Benjamin ConleyAug 31, 2025
      If the screen flickers when the mouse moves or when programs are called on your Siemens Industrial PC, it may be due to missing DDC information. To resolve this, use a monitor that supports DDC, a KVM switch that passes through DDC information, or a basic cable adapter with DVI-I to VGA connector.
  • V
    Valerie BenitezSep 3, 2025
    What to do if the DVD/CD front loader on my Siemens Simatic IPC647C doesn't open?
    • J
      jamie59Sep 3, 2025
      If the front loader on your Siemens Industrial PC DVD/CD drive doesn't open, it may be because the device is switched off or the open/close button is disabled by software. To manually remove the data medium, switch off the device, then insert a pointed object (like a pin or opened paper clip) into the emergency extraction opening of the drive. Apply slight pressure until the front loader opens, then pull the loader further out.
  • M
    Melissa SilvaSep 6, 2025
    How to fix boot from RAID array after hard disk change on Siemens Simatic IPC647C?
    • B
      Breanna WolfeSep 6, 2025
      If, after changing the hard disk on your Siemens Industrial PC, the system does not boot from the RAID array, set the RAID array to be first in the boot priority order.
  • W
    wwuSep 9, 2025
    What does 'unused' SATA port mean after hard disk change on Siemens Industrial PC?
    • R
      Robyn StevensSep 9, 2025
      If, after changing the hard disk on your Siemens Industrial PC, 'unused' is indicated for the relevant SATA port, reboot the system with a functioning hard disk. This issue may occur if the system was booted without a functioning hard disk, possibly because the removable rack was not switched on.
  • L
    lynchjackSep 12, 2025
    How to correct the time and date on a Siemens Simatic IPC647C Industrial PC?
    • Z
      Zachary KnightSep 12, 2025
      To correct an incorrect time and/or date on your Siemens Industrial PC, press during the boot sequence to enter BIOS Setup and adjust the time and date settings.

Summary

Safety notes

General safety instructions

Details critical safety warnings and legal compliance for device operation.

Description

Function

Describes the integrated monitoring and diagnostic functions of the device.

Features

Lists detailed general, design, enclosure, drive bay, and slot features.

Application planning

Installing

Installing the device

Details optional installation locations and mounting methods for the device.

Connecting

Connecting peripherals

Provides notes and precautions before connecting external peripherals to the device.

Connecting the device to power

Explains how to safely connect the device to the mains power supply.

Commissioning

Requirements for commissioning

Outlines necessary preparations and notes before putting the device into operation.

Initial Commissioning - Initial Startup

Details the procedure for the first-time setup of the operating system.

Integration into an automation system

Integration

Describes options for integrating the PC into existing or planned system environments.

PROFINET

Details the PROFINET interface and related documentation for industrial Ethernet.

Functions

Temperature monitoring;display

Explains how temperature is monitored and potential causes of errors.

Expansions and parameter assignment

Service and maintenance

Removing and installing hardware components

Covers procedures for repairs, preventive maintenance, and replacement of hardware components.

Reinstalling the software

Provides procedures for reinstalling software, drivers, and updating the OS.

Alarm, error, and system messages

BIOS beep codes

Lists POST codes relevant to users, their meaning, description, and remedy.

Boot error messages

Details on-screen error messages during the boot process and their troubleshooting.

Troubleshooting;FAQs

General problems

Offers tips for localizing and troubleshooting common operational problems.

Technical specifications

General specifications

Provides comprehensive technical data on the device's general specifications and standards.

Detailed descriptions

BIOS Setup

Covers BIOS Setup overview, starting, menus, and specific configurations.

Siemens Simatic IPC647C Specifications

General IconGeneral
TypeIndustrial PC
ProcessorIntel Core i7
ChipsetIntel Q170
Operating SystemWindows 10 IoT Enterprise
Ethernet2 x Gigabit Ethernet
Protection ClassIP20
Power Supply100-240 V AC, 50-60 Hz
Operating Temperature0°C to 50°C
Relative Humidity5 to 85% (non-condensing)
DisplayNo integrated display
PortsDisplayPort
Serial Ports2 x RS232/422/485
Slots2 x PCIe x16, 1 x PCIe x4, 4 x PCI

Related product manuals