SIMATIC RF300
System Manual, Release 04/2006, J31069 D0166-U001-A2-7618
3-1
System overview
3
3.1 3.1 RFID systems
RFID systems from Siemens control and optimize material flow. They identify reliably,
quickly and economically, are insensitive to contamination and store data directly on the
product.
Identification
system
Frequency Range,
max.
Memory,
max.
Data transfer
rate (typical) in
byte/s
Temperature,
max.
Special features
RF300 13.56 MHz 0.1 m 20 byte
EEPROM,
32 KB
FRAM
3750 Reader:
-25 °C to +70 °C
Transponder:
-40 °C to +85 °C
IQ-Sense interface
available;
integrated diagnostic
functions;
battery-free data
memory
MOBY D 13.56 MHz 0.8 m 112 byte
EEPROM
110 + 85 °C or
+ 200 °C
SmartLabels based on
ISO 15693
e.g. Tag-it/I-Code
MOBY E 13.56 MHz 0.1 m 752 byte
EEPROM
350 + 150 °C Battery-free data
memory
MOBY I 1.81 MHz 0.15 m 32 KB
FRAM
1250 + 85 °C or
+ 220 °C cyclic
Battery-free data
memory