RF300 system planning
4.4 Installation guidelines
SIMATIC RF300
System Manual, Release 04/2006, J31069 D0166-U001-A2-7618
4-37
Reduction of field data: Transponder and RF350R reader with ANT30
Table 4-8 Reduction of field data by metal (in %): Transponder and RF350R with ANT30
Mounting the antenna
Transponder
Without metal
flush-mounted
in metal
(20 mm surround;
20 mm deep)
RF320T
Without metal 100 80
On metal; distance 20 mm 100 80
Flush-mounted in metal; distance all-round
20 mm
100 80
RF340T
Without metal 100 80
on metal 80 65
Flush-mounted in metal;
distance all-round 20 mm
70 60
RF350T
Without metal 100 80
on metal 70 60
Flush-mounted in metal;
distance all-round 20 mm
65 55
RF360T
Without metal 1) 1)
On metal; distance 20 mm 1) 1)
Flush-mounted in metal;
distance all-round 20 mm
1) 1)
1) combination not permitted