Accessories
10.1 Wide-range power supply unit for SIMATIC RF systems
SIMATIC RF600
System Manual, 06/2019, J31069-D0171-U001-A22-7618
487
G
For reasons of EMC, the device should also be grounded via the grounding connection ཱི,
which is connected to the primary input (PE)
. Ensure that this connection is as short as
possible and has a cable cross-section of at least 10 mm². This will ensure that any faults
occurring on the shielding can be dissipated as well as possible.
The grounding connection
ཱི must be electrically connected to the ground potential using a
contact disc. Tighten the screw with a torque of ถ 1.5 Nm.
(b) Flat washer
(d) Contact washer:
To make ground contact, use contact wash-
ers according to the Siemens standard: SN
70093-6-FStflNnnc- 480h, Siemens item no.:
H70093-A60-Z3
The wide-range power supply unit for SIMATIC RF systems meets degree of protection
IP67.
Ⴠ Dust-tight: No ingress of dust
Ⴠ Protected against harm from temporary submersion in water: Water must not enter in
amounts that can cause damage, if the housing is immersed in water 1 m deep for 30
minutes.
All information applies only when connected and locked. The assignment of degrees of
protection is subject to standardized test methods. If no secondary cables are connected,
close the secondary sockets with a protective cap.