Accessories
10.1 Wide-range power supply unit for SIMATIC RF systems
SIMATIC RF600
System Manual, 06/2019, J31069-D0171-U001-A22-7618
489
6
-
0
M
Mechanical specifications
x Material x Polyamide, glass-fiber reinforced
x Casting compound: Polyurethane
x Color x Black
P
Permitted ambient conditions
x During operation x -25 … +70 °C
x During transportation and storage x -40 … +85 °C
Self-heating on full-load
ഒ
Degree of protection to EN 60529
Protection class according to SELV/PELV Separation of output voltage according to
EN 60950-1 / EN 50178
Electrical safety EN 60950 / UL 60950 / CAN/CSA 22.2 950, 3
Edition
Conducted interference EN 61000-6-3 / EN 55011
Class B
Noise emission EN 61000-6-3 / EN 55011
Class B
x ESD x EN 61000-6-2 / EN 61000-4-2
Contact discharge: 4 kV
(air discharge): 8 kV
x Burst x EN 61000-6-2 / EN 61 000-4-4
Symmetrical: 2 kV
Asymmetrical: 2 kV
x Surge x EN 61000-6-5 / EN 61 000-4-5
Symmetrical: 1 kV
asymmetrical 2 kV
x HF field x EN 61000-6-2 / EN 61000-4-3
10 V, 3 V, 1 V (80 MHz ... 2.7 GHz)
HF coupling EN 61000-6-2 / EN 61000-4-6
10 V
eff
Line interruption EN 61000-6-2 / EN 61000-4-11