Basic functions
4.3 Triggering of the integrated outputs of the CU 320 Control Unit
Connection of the SINAMICS S120 to the Technology CPU
124 Product Information, 09/2011, A5E00480378-04
4. To set the parameters for the output cam, switch to the
"\Technology\Axes\Axis_1\Output_Cam\Output_Cam_1" dialog in the S7T Config
project navigator.
5. Select the "Activate output" check box.
6. Enter "Hardware address 300" and "Bit number 0" from the
HW Config hardware configuration.
Result
This completes the configuring of the output cam.