Commissioning
3.3 Preparing the connection to the SINAMICS
Connection of the SINAMICS S120 to the Technology CPU
30 Product Information, 09/2011, A5E00480378-04
3.3.4 Activating routing in NetPro
Introduction
To establish an online connection between the programming device and the
SINAMICS S120 drive system, the "Routing of a SIMATIC PC station" in NetPro
must be activated.
This is necessary because the programming device is connected via the X1-MPI/DP
interface to the technology CPU and to the SINAMICS S120 on the PROFIBUS DP (DRIVE)
of the Technology CPU.
To allow the programming device to access the SINAMICS S120 online, a routing must take
place between the X1-MPI/DP interface and the PROFIBUS DP (DRIVE) through the
Technology CPU.
352),%86
'3'5,9(
6,1$0,&66
; ;
5287,1*
3URJUDPPLQJGHYLFH
7HFKQRORJ\&38
EHWZHHQ;DQG;