Expert Functions
5.8 Triggering of a brake
Connection of the SINAMICS S120 to the Technology CPU
Product Information, 09/2011, A5E00480378-04
181
Fast stop (OFF3):
The drive is braked at the fast stop ramp (emergency stop). When the speed threshold is
reached, the holding brake is enabled which disables the pulse enable once the brake
closing time has elapsed.
6SHHGVHWSRLQW
$FWXDOVSHHG
+ROGLQJEUDNH
RSHQ
6ZLWFKLQJ2Q,QKLELWHG
%UDNHFORVLQJWLPH
2))
Q
+ROGLQJEUDNH
t
t
t
t
t