Commissioning
3.4 Configuring the drive components
Connection of the SINAMICS S120 to the Technology CPU
36 Product Information, 09/2011, A5E00480378-04
Procedure
1. Use the Project > Connect to target system menu command to establish an online
connection to the SINAMICS S120 in S7T Config.
2. Place the SINAMICS S120 in the initial state by restoring the factory settings.
To do this, mark "SINAMICS_S120" and select the
Target device > Restore factory settings menu command in the shortcut menu.
Pay attention to any messages and acknowledge them. Also save the factory settings in
the ROM of the drive.