EasyManua.ls Logo

Siemens Simatic S7-300 - Page 52

Siemens Simatic S7-300
208 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Commissioning
3.4 Configuring the drive components
Connection of the SINAMICS S120 to the Technology CPU
52 Product Information, 09/2011, A5E00480378-04
15. Configure the motor holding brake, if there is one, and click "Next" to confirm the setting.
For motor holding brakes which are a direct component of the motor block, use the
"Motor holding brake acc. to sequential control" setting. For externally fitted motor holding
brakes, select the "Motor holding brake acc. to sequential control, brake connection via
BICO interconnection" setting, and also link it to a free output.
In both cases, you must enable the "Extended brake control" option.