Technical specifications
5.3 Electromagnetic compatibility
Comfort Panels INOX PCT
40 Compact Operating Instructions, 07/2021, A5E38804191-AE
Pulse-shaped disturbance
The following table shows the electromagnetic compatibility of modules with regard to pulse-
shaped interference. The precondition for electromagnetic compatibility is that the HMI
device meets the specifications and guidelines for electrical installation.
Pulse-shaped interference Tested with Performance
level equiva-
lence
Electrostatic discharge
in accordance with
IEC 61000-4-2
Air discharge: 8 KV
3
Contact discharge: 6 kV (front)
Contact discharge: 4 kV (rear)
2
Bursts
(high-speed transient inter-
ferences)
in accordance with
IEC 61000-4-4
2 kV supply cable
1 kV signal line, < 30 m
3
2 kV signal line, > 30 m
4
High-energy single pulse
(surge) in accordance with
IEC 61000-4-5
1
Asymmetrical coupling:
1 kV supply cable, DC voltage
2
1 kV signal line/data cable, > 30 m
Symmetrical coupling:
0.5 kV power cable, DC voltage
2
1 kV signal line, > 30 m
3
1
The following applies to Comfort V1/V1.1 devices: External protective circuit required, see Function
Manual "Designing interference-free controllers", section 7 "Lightning protection and overvoltage
protection"
You can find the Function Manual "Designing interference-free controllers" for download on
the Internet (https://support.industry.siemens.com/cs/ww/en/view/59193566
).
Sinusoidal interference
The following table shows the EMC behavior of the modules with respect to sinusoidal
interference. This requires the HMI device to meet the specifications and directives for
electrical installation.
Sinusoidal interference
Test values
HF radiation (electromagnetic fields)
according to IEC 61000-4-3
Comfort V1/V1.1 devices:
80% amplitude modulation at 1 kHz
to 10 V/m from 80 MHz ... 1 GHz
to 10 V/m from 1.4 GHz ... 2 GHz
to 1 V/m from 2 GHz ... 2.7 GHz
Comfort V2 devices:
80% amplitude modulation at 1 kHz
To 10 V/m in the range 80 MHz to 1 GHz
To 3 V/m in the range 1.4 GHz to 6 GHz
HF current feed on cables and cable
shields according to IEC 61000-4-6
Test voltage 10 V with 80% amplitude modulation at 1 KHz
in the 10 KHz to 80 MHz range
Magnetic field intensity
50/60 Hz; 100 A/m RMS