Technical specifications
5.3 Electromagnetic compatibility
Comfort Panels INOX PCT
40 Compact Operating Instructions, 07/2021, A5E38804191-AE
Pulse-shaped disturbance
The following table shows the electromagnetic compatibility of modules with regard to pulse-
shaped interference. The precondition for electromagnetic compatibility is that the HMI
device meets the specifications and guidelines for electrical installation.
Pulse-shaped interference Tested with Performance
level equiva-
in accordance with
IEC 61000-4-2
Contact discharge: 6 kV (front)
Contact discharge: 4 kV (rear)
(high-speed transient inter-
ferences)
in accordance with
2 kV supply cable
1 kV signal line, < 30 m
(surge) in accordance with
IEC 61000-4-5
1
1 kV supply cable, DC voltage
• 1 kV signal line/data cable, > 30 m
0.5 kV power cable, DC voltage
• 1 kV signal line, > 30 m
The following applies to Comfort V1/V1.1 devices: External protective circuit required, see Function
Manual "Designing interference-free controllers", section 7 "Lightning protection and overvoltage
You can find the Function Manual "Designing interference-free controllers" for download on
the Internet (https://support.industry.siemens.com/cs/ww/en/view/59193566
).
Sinusoidal interference
The following table shows the EMC behavior of the modules with respect to sinusoidal
interference. This requires the HMI device to meet the specifications and directives for
electrical installation.
HF radiation (electromagnetic fields)
according to IEC 61000-4-3
80% amplitude modulation at 1 kHz
• to 10 V/m from 80 MHz ... 1 GHz
• to 10 V/m from 1.4 GHz ... 2 GHz
• to 1 V/m from 2 GHz ... 2.7 GHz
80% amplitude modulation at 1 kHz
• To 10 V/m in the range 80 MHz to 1 GHz
• To 3 V/m in the range 1.4 GHz to 6 GHz
HF current feed on cables and cable
shields according to IEC 61000-4-6
Test voltage 10 V with 80% amplitude modulation at 1 KHz