USB-Prommer
12 Commissioning Manual, 04/2020, A5E50041544-AA
Fault Diagnostics
7
You can remedy simple faults that you can diagnose yourself as follows:
Fault/Cause
Remedy
POWER LED does not light up in yellow
USB cable not plugged in
PC is switched off
PC and SIMATIC USB-Prommer are in pow-
er-saving mode (Hibernate mode).
SIMATIC USB-Prommer is not recognized by
the PC.
SIMATIC Memory Cards and SIMATIC Micro
Memory Cards cannot be edited.
Hardware fault exists
Plug in USB cable
Switch on the PC
Permissible operating mode
Installing drivers
Check the version of the SIMATIC STEP 7
software
Contact Customer Support or your Siemens
contact person.
POWER LED does not light up in green
USB cable not plugged in
Plug-in power supply not plugged in or defec-
tive
Plug in USB cable
Plug in or replace plug-in power supply
Continuous flashing at the POWER LED
Hardware fault exists If the POWER LED of the device continues
flashing after the USB cable and the plug-in
power supply have been plugged in repeated-
ly, the device is defective and must be re-
placed.
Contact Customer Support or your Siemens
contact person.