Preface
viii
Siemens AG, 2004. All rights reserved
Induction Motors, 1PH7 (APH7S) – 05.04 Edition
Danger and warning information
!
Danger
Start-up/commissioning is absolutely prohibited until it has been completely
ensured that the machine, in which the components described here are to be
installed, is in full compliance with the specifications of Directive 98/37/EC.
Only appropriately qualified personnel may commission SIMODRIVE units and
AC motors.
This personnel must carefully observe the technical customer documentation
belonging to this product and be knowledgeable about and carefully observe
the danger and warning information.
Operational electrical equipment and motors have parts and components which
are at hazardous voltage levels.
Hazardous axis motion can occur when working with the equipment.
All work must be undertaken with the system in a no-voltage condition
(powered-down).
SIMODRIVE drive units are generally designed for operation on low-ohmic,
grounded line supplies (TN line supplies). For additional information please
refer to the appropriate documentation for the drive converter systems.
!
Warning
Perfect and safe operation of these units and motors assumes professional
transport, storage, mounting and installation as well as careful operator control
and servicing.
The information provided in catalogs and quotations additionally applies to
special versions of units and motors.
In addition to the danger and warning information/instructions in the technical
customer documentation supplied, the applicable domestic, local and
plant-specific regulations and requirements must be carefully taken into
account.
!
Caution
The motors can have surface temperatures of over +100 C.
This is the reason that temperature-sensitive components, e.g. cables or
electronic components may neither be in contact nor be attached to the motor.
When handling cables, please observe the following:
They may not be damaged
They may not be stressed
They should not come into contact with rotating components.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens Simodrive 1PH7 and is the answer not in the manual?

Siemens Simodrive 1PH7 Specifications

General IconGeneral
BrandSiemens
ModelSimodrive 1PH7
CategoryEngine
LanguageEnglish

Related product manuals