04/96
Siemens AG 2001 All rights reserved 6FC5198jAB40
1–185
SINUMERIK 840C / SIMODRIVE 611D (DA)
300500 System error drive POWER ON
Cyclic after control powerup
a) Error occurs during the ramp-up phase
S Ramp-up phase is stopped
S Pulse or servo disable
S SIMODRIVE_READY and DRIVE_READY are cancelled
Error No.
F...
Additional
information
(xx = for diagno-
stic purposes)
Explanation Remedy Relevant for
F001 (only for
drive SW 1.x).
For drive soft-
ware > SW 2.x,
see F034 or
F035.
Incorrect
address / xx
In the program memory test, it was
found during power-up that the writ-
ten bit pattern could not be read
back. Cause: Hardware error on the
servo control module.
Replace servo control module. FDD
F002 Incorrect
address / xx
In the data memory test, it was
found during power-up that the writ-
ten bit pattern could not be read
back. Cause: Hardware error on the
servo control module.
Replace servo control module. FDD / MSD
F007 xx / xx In the clock pulse synchronization
between NC and drive, an illegal
state has been read from the hard-
ware. Synchronization could not be
performed.
Replace servo control module. FDD / MSD
F01B xx / Axis No.
xx = 0: Error
S A current of 0 is expected dur-
ing powerup of the current ac-
tual value measurement and
during cyclic operation on a
pulse disable, since the system
assures that no current can
flow. It is possible that the
hardware for the current actual
value measurement is defec-
tive.
S Replace the control module.
Check the connections.
Connect the power section
FDD / MSD
In the event of a fault, record additional information and inform hotline.
Error No.
F...
Additional
information
(xx = for diagno-
stic purposes)
Explanation Remedy Relevant for
xx = 1: Power
section not
connected
S A current of 0 is expected dur-
ing powerup of the current ac-
tual value measurement and
during cyclic operation on a
pulse disable. If a 1–axis
power section is addressed via
the module selection (software
configuration of the power sec-
tion) as a 2axis power sec-
tion, the current actual value
measurement outputs this sys-
tem error, since a current > 0 is
measured (NB: the software
configuration and the installed
hardware (power section
and/or control module) do not
match).
S Change the software con
figuration of the power
section (2axis power
section–––> 1axis power
section), or
Deactivate the 2nd axis,
or
Install the 2axis power
section
F020 xx / xx On a single-axis module, an attempt
is made by the NC to activate the
second axis. Possibly faults in com-
munication via the drive bus or
servo control module defective.
Replace servo control module.
Check plug-on connections, take
measures to eliminate noise (scree-
ning, check ground connections).
FDD / MSD
F021 xx / xx On a single-axis module, an attempt
is made by the NC to activate two
axes. Possibly faults in communica-
tion via the drive bus or servo con-
trol module defective.
Replace servo control module.
Check plug-on connections, take
measures to eliminate noise (scree-
ning, check ground connections).
FDD / MSD
F022 xx / xx In at least one axis of the drive mo-
dule, the motor measuring system is
not implemented or it is defective.
Since the components used in the
measuring systems are detected by
the NC and this information is pas-
sed on to the drive, faults in com-
munication by the drive bus could
be the cause.
Replace servo control module.
Check plug-on connections, take
measures to eliminate noise (scree-
ning, check ground connections).
FDD / MSD
Scan
Effect
Explanation
Note
1 Alarms
1.5.1 Alarm description
07/97

Table of Contents

Other manuals for Siemens SIMODRIVE 611-D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMODRIVE 611-D and is the answer not in the manual?

Siemens SIMODRIVE 611-D Specifications

General IconGeneral
BrandSiemens
ModelSIMODRIVE 611-D
CategoryControl Unit
LanguageEnglish

Related product manuals