Page #20 background imageLoading...
Page #20 background image
04/96
Siemens AG 2001 All rights reserved 6FC5198jAB40
1–12
SINUMERIK 840C / SIMODRIVE 611D (DA)
27 Data input disabled V.24 POWER ON
S On reading data into the NC via the computer link
No data has been read in
S The Cycle lock interface signal (DB 48 D0.11) is present
S An attempt has been made to read in NC machine data in normal mode
S An attempt has been made to transfer UMS data to the NC although the UMS was not enabled or not plugged
in.
S Reset DB 48 DW 0 bit 11 via PLC STATUS
S Enter new NC machine data
Applies up to SW 2 only
29 Block >254 characters V.24 POWER ON
S On reading tool data into the NC via the computer link
S Computer link transmission interrupted
S Last block declared invalid
The block read in has more than 254 characters (counting all characters read in, including blanks, CR, LF, etc.)
Divide the block into two or more blocks. The number of the faulty block is displayed.
Applies up to SW 2 only
30 Part program memory overflow V.24 POWER ON
S While reading programs in via the computer link of the NC
S Computer link transmission interrupted
S Last block declared invalid
The maximum memory space for part programs is already assigned
S Delete old programs to release memory for the reading in of new programs. The number of the faulty block is
displayed.
Applies up to SW 2 only
31 No more part program input V.24 POWER ON
S On reading in via computer link
No data has been read in
The part program memory available has been used up.
S Read and delete old part programs no longer required in order to provide more memory.
Applies up to SW 2 only
32 Data format error V.24 POWER ON
S On reading data into the NC via the computer link
S Computer link transmission interrupted
S Last block declared invalid
S The number of decades used after an address is not permissible
S The decimal point occurs in the wrong place
S Part programs or subroutines are not defined or concluded correctly (check header)
Check the program to be read in. The number of the faulty block is displayed.
Applies up to SW 2 only
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
Note
1 Alarms
1.5.1 Alarm description

Table of Contents

Other manuals for Siemens SIMODRIVE 611-D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMODRIVE 611-D and is the answer not in the manual?

Siemens SIMODRIVE 611-D Specifications

General IconGeneral
BrandSiemens
ModelSIMODRIVE 611-D
CategoryControl Unit
LanguageEnglish

Related product manuals