04/96
Siemens AG 2001 All rights reserved 6FC5198jAB40
1–199
SINUMERIK 840C / SIMODRIVE 611D (DA)
300711 Monitoring clock pulse axially not equal POWER ON
POWER ON
Drive only ramps up to ramp-up state 2
On 2-axis modules, the monitoring clock pulse MD 1002 must be identical for both axes.
Set the monitoring clock pulse to be identical for both axes.
Applies as from SW 3
300712 Dynamic response setting not possible (2 axes) POWER ON
POWER ON
Drive only ramps up to ramp-up state 2
For two active axes on a module, it is not possible to change the controller structure via MD 1004.
With two active axes on a module, configuration structure MD 1004 must be set to i before n.
Applies as from SW 3
300713 Shift of position controller clock pulse invalid POWER ON
POWER ON
Drive only ramps up to ramp-up state 2
The position controller clock pulse shift specified by the NC is greater than or equal to the position controller clock
pulse.
NC Hotline
Applies as from SW 4
300714 Power section code wrong POWER ON
POWER ON
Drive only ramps up to ramp-up state 2
S The module order number entered in the NC for the drive is not permissible
Additional information for MSD (drive SW 1 only):
Illegal power section code
S The drive has already been booted with a module order number which does not correspond with the module
order number currently set in the NC.
Additional information for MSD (drive SW 1 only):
Actual power section code in MSD and actual power section code in NC
Reselect module in the NC or cancel reboot procedure
Applies as from SW 3
300715 Maximum power section current <= 0 POWER ON
POWER ON
Drive only ramps up to ramp-up state 2
The maximum current of the power section MD 1107 has a value that is less than or equal to 0.
Enter a valid value in machine data MD 1107 Maximum current of power section”.
Applies as from SW 3
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
Note
1 Alarms
1.5.1 Alarm description
07/97

Table of Contents

Other manuals for Siemens SIMODRIVE 611-D

Related product manuals