1FT6 Synchronous Motors
Configuration Manual, (PFT6), 10.2005 Edition, 6SN1197-0AD02-0BP1
6-11
Dimension Drawings
Force ventilated 1FT6 motors
6.2 Force ventilated 1FT6 motors
Fig. 6-10 1FT608 force ventilated with connector, Size 1.5/3
min
-1
plug assignment
rated speed
size 1.5 size 3
-
e Length dimension k and k1 corrected
24.03.04 Fuß/Se
f Revision 11.08.04 Fuß/Re
centre hole
12-pole plug for resolver
17-pole plug for optical encoder
6-pole plug size 1.5 or 3
for power and brake
45
°
±0.
5°
45
°
±
0.5°
3.5
12
Ø 32
k6
58
±0.5
58
±0.5
Ø 130
j6
93
155
194
45
35
10
185
344
3
k = without brake / k1 = with brake
175
140
32
43
137
213
IMB5: ø
11
45
5
45
38
Ø
165
±0.3
150
deviation acc. to DIN 6885 sheet 1
plug for fan port
DIN 332 DR M12
with/without brake IMB5 (IMB14)
1FT6084
1FT6086 80
80
30.0
25.0
33.5
28.5
451
401
497
447
version with featherkey
Z
Z
air entry
d CM 500730 18.08.03 MG/MJ
<=3000
<=6000
>3000
plug size 1.5
plug size 3
1
A
B
C
D
E
F
2 3 4 5 6 7 8
1 2 3 4
A
B
C
D
E
sheet
No..
total
sheet
scale: without
index information date name/respons.
date:
name:
respons.:
dept.: A&D MC EWN K-T
25.03.93
Balling
replacement for:
Siemens AG
Dimension sheet
forced ventilated with plug size 1.5/3
510.37430.01
1
1
1FT608.
Sigraph
DESIGN
g
Grosse-Benne
flange and shaft
tolerances acc. to
DIN 42955
plug direction:
transverse - right transverse - left axial - NDE axial - DE
not toleranced
dimensions ±1mm
IMB14: M10
max.
stud torque
for fixing bolt
M = 42 Nm
A
g MSt/DGBCM 501275 03.03.05
height
shaft
weight
without brake with brake
resolver/encoder
mm kg mmtypee
k k1
Fit tol. Tol.
32 k6
+0.018
+0.002
130 j6
+0.014
-0.011