1FT6 Synchronous Motors
Configuration Manual, (PFT6), 10.2005 Edition, 6SN1197-0AD02-0BP1
1-23
Motor Description
Cooling
Forced ventilation, SH 132
Air flow direction from DE to NDE.
The air is blow through the enclosure corners of the extruded profile using a mounted radial
fan.
Forced ventilation, SH 160
Air flow direction from DE to NDE.
The air is blow through the enclosure corners of the extruded profile using a mounted radial
fan.
Minimum clearance between parts and components mounted by the customer and the air dis-
charge opening
The following minimum clearance must be maintained between parts and components
mounted by the customer and the air discharge opening:
Connection: via terminal box
Supply voltage: 3-ph. 400/480 V AC, 50/60 Hz
Maximum current: 0.4 A
Connection: via terminal box
Supply voltage: 3-ph. 400/480 V AC, 50/60 Hz
Maximum current: 0.8 A
Table 1-7 Minimum clearance to parts and components mounted by the customer
Shaft height [mm] Minimum clearance [mm]
80 20
100 30
132 60
160 80