Motor Description
Cooling
1FT6 Synchronous Motors
1-26 Configuration Manual, (PFT6), 10.2005 Edition, 6SN1197-0AD02-0BP1
Cooling-medium intake temperature
The intake temperatures should be selected so that no moisture condensation forms on the
surface of the motor: T
cool
= T
ambient
–2 °C
The motors are designed for operation up to a cooling medium temperature of +30 °C, but still
maintaining all of the specified motor data. The continuous torque changes for other intake
temperatures.
Table 1-10 Manufacturers of chemical additives
Company Address Telephone/URL
Tyforop Chemie GmbH Hellbrookstr. 5a,
D–22305 Hamburg
URL: www.tyfo.de
Joh.A. Beckiser
Wassertechnik GmbH
Bergstr. 17
D-40699 Erkrath
Tel.: 02104 / 40075
CINCINNATI CIMCOOL
Cincinnati Milacron b. v./
Cimcool Division
Postfach 98
NL–3031 AB Vlaardingen
Tel.: 003110 / 4600660
Fuchs Petrolub AG Friesenheimer Strasse 17
D-68169 Mannheim
Tel.: 0621 / 3802–0
URL: www.fuchs–oil.com
Hebro Chemie GmbH Rostocker Straße
D-41199 Mönchengladbach
Tel.: 02166 / 6009–0
URL: www.hebro–chemie.de
Fa. Hoechst Refer to the Internet address URL: www.hoechst.com
Houghton Lubricor GmbH Werkstrasse 26
D-52076 Aachen
Tel.: 02408 / 14060
Schilling–Chemie GmbH u.
Produktions KG
Steinbeißstr. 20
D-71691 Freiberg
Tel.: 07141 / 7030
Note
These recommendations involve third-party products which we know to be basically suitable.
It goes without saying that equivalent products from other manufacturers may be used. Our
recommendations should be considered as such. We cannot accept any liability for the quality
and properties/features of third-party products.
Cooling-medium intake tem-
perature
= 30°C 35°C 40°C 45°C
De-rating factor 1.0 0.97 0.95 0.92