1FT5
08.95
1FT5/1-4
Siemens AG 1997 All Rights reserved 6SN1197–0AA20
SIMODRIVE 611 (PJ)
Rated
speed
[RPM]
Cable type
6FXV002–
4)
Cross–
section
1)
[mm
2
]
Connec-
tor size
P
rated
[kW]
Rated
drive
converter
current[A]
Motor
current
I
0
[A]
Motor type
1FT5–
M
rated
[Nm]
M
0
[Nm]
4000
2.6
5.5
8
2.2
3.8
5.5
062–VAG71
064–VAG71
066–VAG71
3.2
6.7
9.6
4
7.5
12.5
0.9
1.6
2.3
1
1
1
4x1.5
4x1.5
4x1.5
5VA01–1VV0
5VA01–1VV0
5VA01–1VV0
12
18
22
20.5
26
33
40
7.5
11
13
17
21
10
32
072–0AG71
074–0AG71
076–0AG71
074–0SG71
076–0SG71
102–0AG71
102–0SG71
14.4
21.5
26.0
24.5
31.0
38.5
46.5
25
25
25
3)
25
40
40
40
3.1
4.6
5.4
7.1
8.8
4.2
13.4
1
2
2
2
2
2
3
4x2.5
4x4
4x6
4x4
4x6
4x10
4x16
5VA11–1VV0
5VA12–1VV0
5VA22–1VV0
5VA12–1VV0
5VA22–1VV0
5VA32–1VV0
5VA23–1VV0
6000
0.9
1.3
1.0
0.76
1.0
0.9
034–VAK71
036–VAK71
042–VAK71
1.6
2.3
1.7
4
4
4
0.5
0.6
0.56
1
1
1
4x1.5
4x1.5
4x1.5
5VA01–1VV0
5VA01–1VV0
5VA01–1VV0
2.0 1.65 044–0AK71 3.4 4 1.0 1 4x1.5 5VA01–1VV0
3.7 2.7 046–VAK71 6.3 7.5 1.7 1 4x1.5 5VA01–1VV0
2.6
5.5
8.
12
18
22
20.5
26
2.1
3.0
4.2
5.0
7.0
4.0
12
15
062–0AK71
064–0AK71
066–0AK71
072–0AK71
074–0AK71
076–0AK71
074–0SK71
076–0SK71
4.6
9.8
14.5
21.0
32.0
39.0
36.0
46.0
7.5
12.5
25
25
40
40
40
40
1)
1.3
1.9
2.6
3.1
4.4
2.5
7.5
9.4
1
1
1
2
2
2
2
3
4x1.5
4x1.5
4x2.5
4x4
4x6
4x10
4x10
4x16
5VA01–1VV0
5VA01–1VV0
5VA11–1VV0
5VA12–1VV0
5VA22–1VV0
5VA32–1VV0
5VA32–1VV0
5VA23–1VV0
1 Core type
0 Not a core type
without brake cable: without overall screen A
with overall screen C
with brake cable: without overall screen B
with overall screen D
Lengths
2)
5 m AF
(examples) 10 m BA
15 m BF
18 m BJ
25 m CF
Cables are not included with the motors,
they must be separately ordered.
Actual value cable, refer to Chapter Encoders (GE).
1) Designed for I
0rms
= I
0[100
k]
2/3 ; ambient temperature 40 °C; PVC–insulated cable; brake connection 2 x 1 mm
2
.
2) Cables can be supplied in incremental lengths of 1 meter; length code, refer to Chapter AL S/4.3.
3) With the specified power module, the motor cannot be fully utilized to 100 K winding temperature.
4) 2=Performance cable; 4=Standard cable; Technical data, refer to Catalog NC Z
1FT5 AC servomotors
01.981.1 Characteristics and technical data

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMODRIVE 611A and is the answer not in the manual?

Siemens SIMODRIVE 611A Specifications

General IconGeneral
BrandSiemens
ModelSIMODRIVE 611A
CategoryInverter
LanguageEnglish