Loading...
1FT5
08.95
1FT5/3-1
Siemens AG 1997 All Rights reserved 6SN1197–0AA20
SIMODRIVE 611 (PJ)
Technical data and characteristics
3.1 Speed–torque diagrams
Note
For converter operation on 480 V supply networks, DC link voltages of > 600 V
are obtained. The following restrictions apply:
Motors, shaft heights 36, 48, 63 and 71 may only be utilized to DT=60 K .
Shaft heights 100 and 132 may still be utilized acc. to DT=100 K.
The shift of the voltage limiting characteristics is described in Chapter
ALS/1.1.
The specified thermal limiting characteristics are referred to DT=100 K.
3.1.1 Standard motors
Note
The rotor moment of inertia for 1FT5 motors is specified without tachometer.
1FT5 AC servomotors
3 Technical data and characteristics